Transcatheter aortic-valve replacement with a self-expanding prosthesis
David H. Adams, M.D., Jeffrey J. Popma, M.D., Michael J. Reardon, M.D., Steven J. Yakubov, M.D., Joseph S. Coselli, M.D., G. Michael Deeb, M.D., Thomas G. Gleason, M.D., Maurice Buchbinder, M.D., James Hermiller, Jr., M.D., Neal S. Kleiman, M.D., et al.
Background
We compared transcatheter aortic-valve replacement (TAVR), using a self-expanding transcatheter aortic-valve bioprosthesis, with surgical aortic-valve replacement in patients with severe aortic stenosis and an increased risk of death during surgery.
Methods
We recruited patients with severe aortic stenosis who were at increased surgical risk as determined by the heart team at each study center. Risk assessment included the Society of Thoracic Surgeons Predictor Risk of Mortality estimate and consideration of other key risk factors. Eligible patients were randomly assigned in a 1:1 ratio to TAVR with the self-expanding transcatheter valve (TAVR group) or to surgical aortic-valve replacement (surgical group). The primary end point was the rate of death from any cause at 1 year, evaluated with the use of both noninferiority and superiority testing.
Results
A total of 795 patients underwent randomization at 45 centers in the United States. In the as-treated analysis, the rate of death from any cause at 1 year was significantly lower in the TAVR group than in the surgical group (14.2% vs. 19.1%), with an absolute reduction in risk of 4.9 percentage points (upper boundary of the 95% confidence interval, −0.4; P<0.001 for noninferiority; P = 0.04 for superiority). The results were similar in the intention-to-treat analysis. In a hierarchical testing procedure, TAVR was noninferior with respect to echocardiographic indexes of valve stenosis, functional status, and quality of life. Exploratory analyses suggested a reduction in the rate of major adverse cardiovascular and cerebrovascular events and no increase in the risk of stroke.
Conclusions
In patients with severe aortic stenosis who are at increased surgical risk, TAVR with a self-expanding transcatheter aortic-valve bioprosthesis was associated with a significantly higher rate of survival at 1 year than surgical aortic-valve replacement. (Funded by Medtronic; U.S. CoreValve High Risk Study ClinicalTrials.gov number, NCT01240902. opens in new tab.)
Share
Publications
-
2-Year Clinical and Echocardiography Follow-Up of Transcatheter Mitral Valve Replacement With the Transapical Intrepid System
Vinayak Bapat, Eric Weiss, Sean Pinney, David H Adams, Angie Zhang , Michael Mack, Martin B Leon, et al. -
Optimal timing of Ross operation in children: A moving target?
Igor E Konstantinov, Emile Bacha, David Barron, Tirone David, Joseph Dearani, Yves d'Udekem, Ismail El-Hamamsy, Hani K Najm, Pedro J Del Nido, Christian Pizarro, Peter Skillington, Vaughn A Starnes, David Winlaw -
Mitral Valve Intervention in Elderly or High-Risk Patients: A Review of Current Surgical and Interventional Management
Maheedhar Gedela, Busra Cangut, Lucy Safi, Parasuram Krishnamoorthy, Dimosthenis Pandis, Ahmed El-Eshmawi, Gilbert H L Tang -
Total artificial heart implantation as a bridge to transplantation in the United States
Shinobu Itagaki, Nana Toyoda, Natalia Egorova, Erick Sun, Timothy Lee, Percy Boateng, Gregory Gibson, Noah Moss, Donna Mancini, David H Adams, Anelechi C Anyanwu